Type |
Head-mounted |
Input |
RTD, TC, mV, ohm |
Input RTD |
Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10 |
Input thermocouple |
Type B, C, D, E, J, K, N, R, S, T |
Type of transmitter |
Digital |
Output |
4-20 mA, HART protocol |
Galvanic isolation |
1500 VAC |
Measuring channels |
1 channel |
Sensor connection |
2-, 3-, 4-wire connection |
Power supply |
IPAQ-C530: 8,5 to 36 VDC
IPAQ-C530X: 8,5 to 30 VDC |
Approvals |
ATEX, IECEx, cFMus |
HART® compliance |
Fully compliant with the HART® 7 protocol
as well as the previous HART® 6 and 5. |
Typical accuracy |
Max. ±0.08K or ±0.08% of span |
Accuracy over time |
Max. drift ±0,02% of span/year |
Configuration |
ConSoft, INOR Connect or EDD, DTM / FDT-system |
Wireless connectivity |
NFC® and Bluetooth® * |
Vibration |
IEC 60068-2-6, 10 g |
EMC |
EN 61326-1 and EN 61326-2-3 |
Humidity |
0…98% RH (non-condensing) |
Ambient temperature |
–40…+85 °C / -40…+185 °F |
Runtime counter |
Hour counter for elapsed operational time |
Simulated output |
Fixed current ouput during a maximum time of 15 min |
Adjustable filtering level |
0,17 to 90 s (standard 0.9 s) (3-wire RTD) |
Adjustments – Min. span |
10°C / 18°F or according to the sensor |
Adjustments – Zero point |
Any value within range limits |
Sensor error |
NAMUR NE43 |
Error compensation |
Sensor and system error correction |