Simplified menu

  • Fits basic applications with a user-friendly interface supported by two menus and a streamlined list of parameters
  • Eliminates user complexity often experienced with more advanced controllers and unnecessary features
  • Reduces user training costs and user programming errors

PID auto-tune

  • Provides auto-tune for fast, efficient start-up

Standard bus communications

  • Allows easy product configuration via PC communications protocol and free software
  • Saves time, simplifies programming process and improves reliability of controller setup

Factory Mutual (FM) approved over and under limit with auxiliary outputs

  • Increases user and equipment safety for over and under-temperature conditions

Function key

  • Enables simple, one-touch operation of user-defined, repetitive activities

Touch-safe package

  • Increases installer and operator safety
  • Complies with IP2X requirements

EZ-LINK™ mobile application for iPhone® and Android™

  • Expedites controller setup with intuitive navigation
  • Simplifies setting parameters with plain text names and descriptions
  • Connects quickly and easily via Bluetooth® wireless communications

SMOOTH TOUCH™ keypad

  • Eliminates contamination points on the front of thecontroller
  • Prevents premature failure of mechanical components
  • Creates a better seal on front panel
  • Ensures an easy to clean surface

Agency approvals: UL® listed, CSA, CE, RoHS, W.E.E.E., FM, SEMI F47-0200, Class 1, Div. 2 rating on selected models

  • Assures prompt product acceptance
  • Reduces end product documentation costs

P3T armor sealing system

  • Compiles to NEMA 4X, IP66 and IP67 specifications
  • Allows controller to be cleaned and washed
  • Certified UL® 50 independent to NEMA 4X specification

Consistent Termination Labeling (CTL) connection system

  • Simplifies switching between products
  • Speeds up user’s system documentation

Three-year warranty

  • Demonstrates Watlow’s reliability and product support

High-amperage power control output (1/16 DIN only)

  • Drives 15 ampere resistive loads direct
  • Reduces component count
  • Saves panel space and simplifies wiring
  • Reduces cost of ownership

Product Specifications

Line Voltage/Power

  • 85 to 264VAC, 47 to 63Hz
  • 20 to 28VAC, +10/-15%; 50/60Hz, ±5%
  • 12 to 40VDC
  • 10VA (1/32 and 1/16 DIN)
  • Data retention upon power failure via non-volatile memory
  • Compliant with SEMI F47-0200, Figure R1-1 voltage sag requirements @ 24VAC or higher

Environment

  • 0 to 149°F (-18 to 65°C) operating temperature
  • -40 to 185°F (-40 to 85°C) storage temperature
  • 0 to 90% RH, non-condensing

Accuracy

  • Calibration accuracy and sensor conformity: ±0.1% of span, ±1°C @ the calibrated ambient temperature and rated line voltage
  • Type S: 0.2%
  • Type T below -50°C: 0.2%
  • Calibration ambient temperature @ 77°F ±5°F (25°C ±3°C)
  • Accuracy span: 1000°F (540°C) min.
  • Temperature stability: ±0.1°F/°F (±0.1°C/°C) rise in ambient max.

Agency Approvals

  • cULus® UL/EN/CSA C22.2 No 61010-1 Listed, File E185611
  • CSA C22.2 No. 24, File 158031
  • UL® 50 4X indoor locations, NEMA 4X, IP66, IP67 front seal
  • cULus® ANSI/ISA 12.12.01-2007, CSA-C22.2 No. 213-1987, Class 1, Div. 2, Groups A, B, C and D, temperature code T4A, File E184390 (optional)
  • CE, RoHS by design, W.E.E.E.
  • FM Class 3545 (limit controls)

Controller

  • User selectable heat/cool, on-off, P, PI, PD, PID or alarm action, not valid for limit controllers
  • Auto-tune with control algorithm
  • Control sampling rates: input = 10Hz, outputs = 10Hz
  • Input and output capacity per controller type ordering information

Serial Communications

  • Isolated communications
  • Standard bus configuration protocol

Wiring Termination—Touch-Safe Terminals

  • Input, power and controller output terminals are touch safe removable 12 to 22 AWG

Universal Input

  • Thermocouple, grounded or ungrounded sensors, greater than 20MΩ input impedance, 2kΩ source resistance max.
  • Non-isolated to switched dc and process output
  • RTD 2- or 3-wire, platinum, 100Ω @ 0°C calibration to DIN curve (0.00385 Ω/Ω/°C)
  • Process, 4-20mA @ 100Ω, or 0-10VDC @ 20kΩ input impedance; scalable

Functional Operating Range

  • Type J: -346 to 2192°F (-210 to 1200°C)
  • Type K: -454 to 2500°F (-270 to 1371°C)
  • Type T: -454 to 750°F (-270 to 400°C)
  • Type E: -454 to 1832°F (-270 to 1000°C)
  • Type N: -454 to 2372°F (-270 to 1300°C)
  • Type C: 32 to 4200°F (0 to 2315°C)
  • Type D: 32 to 4200°F (0 to 2315°C)
  • Type F: 32 to 2449°F (0 to 1343°C)
  • Type R: -58 to 3214°F (-50 to 1767°C)
  • Type S: -58 to 3214°F (-50 to 1767°C)
  • Type B: 32 to 3300°F (0 to 1816°C)
  • RTD (DIN): -328 to 1472°F (-200 to 800°C)
  • Process: -1999 to 9999 units

Output Hardware

  • Switched dc = 22 to 32VDC @ 30mA
  • Open collector = 30VDC max. @ 100mA max. current sink
  • Solid state relay (SSR), Form A, 0.5A @ 24VAC min., 264VAC max., opto-isolated, without contact suppression
  • Electromechanical relay, Form C, 24 to 240VAC or 30VDC max., 5A resistive load, 100,000 cycles at rated load
  • Electromechanical relay, Form A, 24 to 240VAC or 30VDC max., 5A resistive load, 100,000 cycles at rated load
  • Output 2 is limit for limit models
  • NO-ARC relay, Form A, 24 to 240VAC, 15A @ 122°F (50°C), resistive load, no VDC, 2 million cycles at rated load
  • Universal process output: range selectable; 0 to 10VDC ±15mV into a min. 1,000Ω load with 2.5mV nominal resolution; 4 to 20mA ±30μA into max. 800Ω load with 5μA nominal resolution; temperature stability 100ppm/°C

Operator Interface

  • Dual 4 digit, 7 segment LED displays
  • Typical display update rate 1Hz
  • Advance, infinity (RESET), up and down keys plus a FUNCTION KEY (not available in 1/32 DIN)
  • Infinity key is also labeled RESET on limit control models
  • FUNCTION KEY on 1/16 DIN package automatically programmed as an auto/manual transfer mode function on PID models.